| System |
| Processors |
Up to 2 Intel® Pentium®
III processors at 933MHz and 1.26GHz
|
|
133MHz front side bus
|
|
32KB Level 1 cache (16KB instruction cache and
16KB two-way write-back data cache)
|
|
256KB Level 2 cache
|
|
ServerWorks HE-SL Chipset
|
| Memory |
128MB - 2GB 133MHz ECC SDRAM memory |
| 4 DIMM sockets on system board |
| Storage |
| Hard Drives |
18GB, 36GB and 73GB (10,000 rpm)
Ultra3 (Ultra160) and 18GB (15,000 rpm) Ultra3 (Ultra160) SCSI hard drives |
| SCSI Controllers |
Dual-channel integrated Ultra3
(Ultra160) SCSI Adaptec® AIC-7899 (160Mb/s) controller |
| RAID Controllers |
Optional PowerEdge Expandable RAID
Controller, Version 3, Dual-Channel Card (PERC 3/DC or PERC 3/DCL) with
64MB cache |
| I/O Slots |
2 x 64-bit/66MHz PCI slots on separate
PCI buses |
| Drive Bays |
Bays for three hot-plug SCSI drives |
| IDE CD-ROM |
| IDE DVD-ROM |
| Standard 3.5" 1.44MB diskette
drive |
| Graphics |
Integrated VGA-compatible, ATI-Rage XL
controller |
| Communications |
Dual Integrated Intel Pro/100+ Server Adapter
|
|
Alteon Gigabit NIC
|
|
Broadcom Gigabit NIC
|
|
Intel Pro 100+
|
|
Intel Dual-Port Pro 100+
|
|
Intel Pro 100S
|
| Input Devices |
Windows SpaceSaver 101-key keyboard |
| Windows Performance 101-key keyboard |
| Dell PS/2-style mouse |
| Chassis |
Rack-Mountable Chassis: 4.3cm (h) x
44.7cm (w) x 61.0cm (d) |
| 1U rack height |
| Weight 16.3 kg. max |
| Drive Bays |
Three hot-plug hard drives |
| I/O Ports |
Two 64-bit/66MHz PCI slots |
| Power |
240 Watts |
| 110/220 Volts |
| Management |
Integrated remote management
|
|
Fault monitoring of voltage, fan, and thermal
conditions to help ensure notification in case of potential problems
|
|
Management of drive array under optional
PowerEdge Expandable RAID Controller
|
|
Tracks memory errors that have been corrected by
the ECC memory
|
|
Automatic Server Recovery will reboot and restart
the server if the OS hangs without user intervention
|
|
User-definable OS thresholds can be set, allowing
administrators to tune systems and eliminate bottlenecks to performance
|
|
Console alerting through Dell OpenManage IT
Assistant keeps administrators informed of server performance or potential
problems
|
|
Asset management features allow customers to
inventory server configuration, CPU, memory and disk
|
|
Dell OpenManage Server Assistant CD included with
every server to get your PowerEdge server up and running
|
| Software |
| Recomended Software |
Microsoft Windows NT Server, Version 4.0
|
|
Microsoft Windows NT Enterprise Edition
|
|
Microsoft Windows 2000 Server
|
|
Microsoft Windows 2000 Advanced Server
|
|
Red Hat® Linux®
7.0, 7.1
|
| Environmental and
Regulatory |
| Environmental |
Operating Temperature: 10º C to 35º C (50º F
to 95º F)
|
|
Storage Temperature: -40º C to 65º C (-40º F
to 149º F)
|
|
Operating Relative Humidity: 8% to 80%
(non-condensing)
|
|
Storage Relative Humidity: 5% to 95%
(non-condensing)
|
|
Operating Vibration: 0.25G at 3Hz to 200Hz for 15
minutes
|
|
Storage Vibration: 0.5G at 3Hz to 200Hz for 15
minutes
|
|
Operating Shock: 6 shock pulses of 41G for up to
2ms
|
|
Storage Shock: 6 shock pulses of 71G for up to
2ms
|
|
Operating Altitude: -16m to 3,048m (-50 ft to
10,000 ft)
|
|
Storage Altitude: -16m to 10,600m (-50 ft to
35,000 ft)
|
| Regulatory |
FCC (U.S. only) Class B
|
|
DOC (Canada) Class B
|
|
CE EN 55022, IEC 801-2, EN50082-1, ICE 801-3,
ICE801-4
|
|
VCCI Class II
|
|
UL 1950
|
|
CSA 950
|
|
EN 60950
|
|
IEC 60950
|
|
CE
|